Pressure Measurement

Solutions

To be able to connect a pressure sensor to a measuring system, the signal needs to be adjusted with a measuring amplifier. BMC Messsysteme GmbH offers perfect solutions with a wide range of measuring amplifiers, such as the MAL- respectively MA-Series. The amplifiers deliver an output signal of +/- 5 volt, which  matches the measuring systems of BMC Messsysteme GmbH in the best way possible.

With the miniature measurement amplifiers of the MAL-Series it is very easy to connect your sensors to the measurement systems of BMC Messsysteme GmbH. With our 5B compatible measurement amplifiers these signals can even be galvanically isolated from the measurement system.

Measurement Software

NextView

Measurement Device

USB-AD16f

  • 16 analog inputs
    (16 bit, ±10V, ±5V, ±2V, ±1V)
  • max. sampling rate 250kHz
  • 2 analog outputs (16 bit, ±10V)
  • analog channels electrically isolated
  • 4 digital inputs and outputs each
    (TTL/CMOS)
  • 1 counter (16 bit, isolated)
  • bus-powered
  • USB 2.0, high-speed

Measurement Amplifier

MAL-SG-Series

  • compact & powerful
  • size: 24-pin DIL IC
  • 50Hz bandwidth
  • differential input
  • MAL-SG2: sensitivity 2mV/V
  • MAL-SG5: sensitivity 5mV/V
  • sensor supply 5V
  • output filter 6dB/oct.

 

Connection Technology

ZU37CB

  • connectors for 16+4 channels
  • 37 jacks for 4mm banana plugs, 18 terminal connectors (4-pin)
  • connect to DAQ system at D-Sub 37 male
  • sensor supply for 16 channels

Complete Package

Now you've got an all-round carefree package for your measurement task. From your sensor to the connection technology, to connecting cables right through to displaying live data of our signals. Best components, combined perfectly.

This combination of our all-in-one AMS-Series in connection with the NextView-Software is an extremely powerful, flexible and yet very compact system, that leaves no wishes unanswered.

Measurement Software

NextView

  • Visualize. Configure.
    Scan. Analyze.
  • Application-oriented.
    No programming.
  • Various versions.
  • Show signals.
    Live or recorded.
  • MultiScan & File Train. (just NV Pro)
  • Trigger & Prehistory. (just NV Pro)

Measurement Device

AMS42-LAN16fx

  • 5B compatible for measurement amplifiers of the MA-Series
  • 8 amplifier inputs, 8 analog inputs (non-amplified)
  • 16 bit, max. 250kHz
  • 2 analog outputs (16 bit, ±10V)
  • 32 digital channels (2x16 bit, TTL/CMOS)
  • 3 counters (32 bit, max. 16 MHz) for pulse, incremental encoder, or pulse-time measurement
  • power supply 12-40V
  • TCP/IP Ethernet (Twisted Pair)
  • synchronized to real-time
  • individual plug-in cassettes installable per channel

Complete Package

Now you've got an all-round carefree package for your measurement task. From your sensor to the connection technology, to connecting cables right through to displaying live data of our signals. Best components, combined perfectly.

Measurement Amplifier

MAL-SG-Series

  • compact & powerful
  • size: 24-pin DIL IC
  • 50Hz bandwidth
  • differential input
  • MAL-SG2: sensitivity 2mV/V
  • MAL-SG5: sensitivity 5mV/V
  • sensor supply 5V
  • output filter 6dB/oct.

 

Connection Technology

ZU37CB

  • connectors for 16+4 channels
  • 37 jacks for 4mm banana plugs, 18 terminal connectors (4-pin)
  • connect to DAQ system at D-Sub 37 male
  • sensor supply for 16 channels

Complete Package

Now you've got an all-round carefree package for your measurement task. From your sensor to the connection technology, to connecting cables right through to displaying live data of our signals. Best components, combined perfectly.
Special Price from 987,- €*

* Manufacturer's suggested retail price: Our offer is addressed to industrial and commercial customers plus VAT applicable in the different countries. Prices abroad can differ.

In Detail

To give your application a complete measurement system you will need several components. Below we offer a perfect solution from our modular product range, preconfigurated and optimized in price and value.
Of course all components can be adjusted to your individual needs. Our team is more than happy to help any time via phone or mail.

Pressures can be measured in gaseous and liquid media as well as a force transporting component on solid objects. Pressure is usually a slow changing signal. It is a standard procedure to measure atmospheric pressure and air pressure. Another important measured signal is hydraulic pressure.

Pressure sensors react very delicately on overstressing. When the measuring range has been exceeded, the sensor can easily be damaged beyond repair, depending on the used technology. To cover the diverse requirements of the different applications in the best way possible, there are various kinds of sensors available. All sensor principles define the pressure indirect via the deformation of an elastic element. In the sector of pressure technology there are variations of inductive, capacitive, strain gauge and piezo-resistive pressure sensors.

Go back